The impact of commercial refrigeration compressor (2)
The impact of commercial refrigeration compressor (2)
4. Starter damage The starter is damaged, causing the compressor start winding circuit to be unable to be connected at the moment of power-on, and there is no current in the start winding, and the compressor cannot be formed Rotating magnetic field, so it doesn't work. Features: The door light is on, the compressor does not run, but it sounds clicks , and the measured commercial refrigeration current is 6A, x, 12A. The measured PTC starting resistance is far from the marked value. The heavy hammer starter measures the forward and inverted resistance, and it cannot change well between on and off. Repair method: replace the starter of the same model.
5. Compressor coil is open and the compressor is running or starting to bypass the open circuit, causing the compressor to lose one magnetic field and fail to operate. Features: The door light is on, the compressor does not run, and some also make a click sound. Test the compressor inlet line with 220V voltage, unplug the compressor power supply and compressor accessories, measure the resistance between the three terminals of the compressor, there are two The resistance between the two terminals is infinite. Repair method: replace the compressor of the same model.
6. commercial refrigeration Compressor jammed cylinder or pumping shaft compressor's mechanical parts are stuck and do not move, so that the compressor does not operate. Features: door lights are on, the compressor does not operate, most of them make buzzing or clicking , Measure that the compressor inlet has a voltage of 220V, and the resistance between the measured compressor terminals is normal. Maintenance method: Replace the compressor of the same model: You can also try to repair it by vibration method, capacitor activation method, voltage activation method, and reversal method.
7. commercial refrigeration The failure rate of the power cord is very low. If the power cord is broken, the compressor will not be able to operate without voltage. Features: The door light is not on, the compressor does not operate, and does not make any noise. There is no AC 220V voltage in the commercial refrigeration line. Repair method: replace the power cord of the same specification.
The above articles are from refrigerated showcase commercial refrigeration and vertical commercial refrigeration. For details, please log in: www.ihdjx.com
free order hotline: +86 1801956n
>>
keywords:
Ranking of similar articles
- refrigerated showcase Refrigeration Equipment Co., Ltd. growth process
- Watermelon fresh-keeping refrigerator can better preserve the nutrients of watermelon
- Refrigerated showcase ltd. refrigeration has been a leader in innovation and energy saving
- The advantage of western restaurant made salad bar - refrigerated showcase
- Refrigerated showcase warm, kick off the new offers
- Don't put the frozen food in shenzhen supermarket display cooler, rapid freezer storage in shenzhen more than two
- Supermarket walk - cooler in fruits and vegetables preservation equipment
- Refrigerated showcase display cooler company 2012 annual celebration
- How to enhance the international competitiveness of the display cases industry
- display cases refrigeration but noisy maintenance (2)
- Commercial refrigeration secondary failure machine noise is large (two)
- Selection of expansion valve in display cases (2)
- Display cooler evaporator embedding and production
- Supermarket commercial refrigeration price range of refrigeration products directly affect the market
- Supermarket refrigerated showcase, supermarket refrigerated showcase, frozen ark excess capacity
- The accelerated development of supermarket refrigerated showcase is conducive to stimulating consumption
- General principles of design and layout of display cooler refrigeration system (3)
- General principles for the design and layout of walk-in cooler refrigeration systems (2)
- The green and energy-saving supermarket supermarket refrigerated showcase has been improving
- display cases The personal hygiene impact of the staff
Latest news articles
- May 2011 refrigerated showcase Qingyuan Tour
- refrigerated showcase Refrigeration Equipment Co., Ltd. growth process
- Refrigerated showcase major sales walk - cooler in class
- Refrigerated showcase display cooler written commercial display cooler legend
- Refrigerated showcase walk - in cooler energy-saving progresses steadily
- 2012 take care of the old man from the supermarket refrigerated showcase
- refrigerated showcase Tip: Which fruits are not suitable for placing in the fruit refrigerated showcase
- Dragon fruit reveals ark makes pitaya ornamental fruit
- Watermelon fresh-keeping refrigerator can better preserve the nutrients of watermelon
- Represent the frozen watermelon fruit for storage
- Hairy crabs freezer frozen taste more fresh
- How hairy crabs fresh refrigerated showcase display cooler tell you
- Large supermarket display ark how to choose the right goods
- Small convenience store owner should show how to choose the convenience stores ltd. refrigeration
- Refrigerated showcase ltd. refrigeration has been a leader in innovation and energy saving
- In September 2012, refrigerated showcase west chung
- Refrigerated showcase walk - in cooler cleaner which aspects should be paid attention to
- Correctly use refrigerated showcase supermarket refrigerated showcase the matters needing attention
- , a refrigerated display showcase meat cooler features of the product
- Refrigerated showcase walk - in the cooler is icy