Repair of mixed working fluid and fluorine-free walk-in cooler

author:  supermarket refrigerated showcase category:  commercial refrigeration Views:  523Time:  2016-08-22
(2) The material to be dedicated compressor and filter drier must be of the same model, usually HX-7 or HX-9. Other devices in contact with refrigerant should also be dedicated. The copper tubes and system-related components used in the R12 system cannot be used in the R134a system. If used, it can be used after washing with trichloroethylene. When welding refrigeration pipes, it is best to use dry flux. If there is no dry flux, copper electrode or trace electrode can also be used.