What are the common failure characteristics and maintenance of display cooler

author:  supermarket refrigerated showcase category:  display refrigerator Views:  518Time:  2016-08-22
Exposed refrigeration pipeline leakage 95% of the leakage points in this part have oil stains or black welds, the cooling effect of the display cooler gradually deteriorates, the total pressure does not leak, and the high pressure leaks. Because there is a refrigerating oil cavity in the compressor, and the refrigerating oil is compatible with the refrigerant, oil stains can usually be seen on the surface of the leak when the refrigeration pipeline leaks. The total pressure gauge is generally 0.5MPa, and the high-pressure pipeline micro-leakage needs to be hit with a pressure of 1.2MPa to detect.
Maintenance method: First, open the refrigeration system to bleed, suppress and find the leak (usually at the oily spot), after repairing the welding, the refrigeration system is evacuated, filled with refrigerant, tested, and sealed.
leakage of the anti-exposure tube This part of the leak usually causes the display cooler to suddenly become uncooled, and there is corrosion on the side of the freezer compartment of the middle door frame. Generally, the total pressure does not leak, and some of the high pressure leaks, and some do not leak. Repair method: remove the anti-exposure tube and use it. Remove the anti-dew tube, the display cooler will lose the anti-dew function, but it will not affect the cooling.
The leakage of the internal evaporator of the display cooler causes the cooling effect of the display cooler to gradually deteriorate, and the total pressure or low pressure is leaked. Maintenance method: re-inlay the finished product or self-made evaporator, blow through the system, and check the tightness of the system After it is normal, evacuate, add refrigerant, test machine, and seal.
The above articles are from refrigerated showcase walk-in cooler and display cooler. For details, please log in: www.ihdjx.com