Commercial refrigeration refrigeration failure and maintenance method
author: supermarket refrigerated showcase category: commercial refrigeration Views: 567Time: 2016-08-22
refrigeration failure and maintenance method
if there is no special instruction, the refrigeration maintenance is poor Often accompanied by non-stop or long start-up time and short downtime. No boot description in each fault. Before repairing a commercial refrigeration refrigeration system, it is necessary to distinguish whether it is a direct cooling type, an indirect cooling type or a dual temperature dual control type: and then distinguish whether it is a failure machine or a second failure machine.
if the machine fails, first observe whether the exposed pipeline (focus on the weld) has oil stains, blackening or dust damp, be careful; secondly, observe whether the door frame has any Rust. In this way, the key inspection parts can be determined. If there is oil stains, or welding joints black, dust and oil stains, which are mainly caused by refrigerant leakage, the inspection should be focused on whether there is leakage; if the middle door frame is corroded, focus on whether the anti-dew tube is checked Leakage: There is neither oil nor rust, indicating that the
commercial refrigeration may have internal leakage (low pressure leakage) or poor compressor performance.
the secondary failure machine, but also to observe whether the return pipe is frosted, whether the noise increases during the compressor startup, and whether the condenser heat changes uniformly. If the return air is frosted, it is because the refrigerant is overfilled. If the compressor starts, the noise becomes louder at a normal moment. It is caused by the welding blockage of the refrigeration pipeline; if the compressor is running, there are snoring noise or local condenser overheating , The local normal temperature is caused by unclean evacuation. For indirect cooling machines, observe the frosting of the evaporator and the operation of the fan. If the evaporator is thickly frosted, check the defrosting circuit; if the fan is not running, check the fan motor and switch. For dual-temperature dual-controllers, if the refrigerating room is poor, check the refrigerating thermostat first, and then check the refrigeration system.
[Note] ①If fluorine-free
commercial refrigeration is used for maintenance, the filter drier must be replaced after the refrigeration system is repaired, and the original filter drier cannot be used after activation treatment.
>
② For models using R134a refrigerant, the compressor opening time cannot exceed 50 minutes.
③ R600a refrigerant compressor cannot be turned onFor shell repair, it is necessary to replace the compressor of the same type with the yellow flame-proof mark.
poor cooling and downtime for several hours. Trouble phenomenon: poor cooling, can automatically start and stop, every 30 minutes or so, automatically stop for several hours. When the compressor is running, the condenser has 2/ 3 heat, and the heat changes uniformly. Failure analysis: The refrigeration system is normal, and the thermostat performance is deteriorated. For models with a
commercial refrigeration ambient temperature of 15°C, the temperature of the refrigerating room will rise slowly and the thermostat will have difficulty starting. Troubleshooting: Check and repair according to the ambient temperature of commercial refrigeration. For models with an ambient temperature higher than 16℃, directly replace the thermostat of the same model and pay attention to the number of turns of the temperature sensing tube coil to be roughly the same as the original one. For models with ambient temperature lower than 15℃, first turn on the low temperature compensation switch to test the machine. If there is no change, first replace the thermostat of the same model, and then check the low temperature compensation heating circuit, the components in the dotted frame. Measure the resistance at both ends of the heater and the compensation switch in turn. If the resistance value is infinite, it means that the device under test is damaged.
poor cooling and abnormal appearance. The abnormal appearance is mostly the point of failure. For example, if there is oil stains in the refrigeration pipeline on the back of the commercial refrigeration body or at the welded joints, 95% of the oil stains are leaking; the side of the freezer compartment of the middle door frame is rusted, and 90% is the leakage of the anti-dew pipe in the door frame; the evaporator pipe is corroded , 50% corrosive leak: abnormal noise when the compressor is running, mostly due to insufficient compressor exhaust. Basic maintenance sequence: open the compressor process nozzle to vent and observe the refrigerant discharge, after suppressing the system, use soapy water to check for leaks, and test the compressor exhaust pipe to determine the fault.
the above articles are from refrigerated showcase commercial refrigeration, commercial refrigeration prices, please visit www.ihdjx.com
free order hotline: +86 18019567573
keywords:
Ranking of similar articles
- Large supermarket display ark how to choose the right goods
- , a refrigerated display showcase meat cooler features of the product
- In September 2012, refrigerated showcase west chung
- Correctly use refrigerated showcase supermarket refrigerated showcase the matters needing attention
- Refrigerated showcase ltd. refrigeration New Year's day holiday notice
- Refrigerated showcase walk - in cooler tell you: frozen and refrigeration technology
- How to choose suits own walk - at low temperature in the cooler
- The food hygiene safety need to display cases, walk - in the support of the cooler
- Supermarket glass door display walk - cooler in supermarket refrigerated showcase the price
- How to choose and horizontal display cooler supermarket refrigerated showcase prices
- How to deal with the poor sealing of the medical supermarket refrigerated showcase
- How to discern bad inside freezer part
- Construction of vaccine cold storage requirements?
- Supermarket display cases which style is more energy-saving
- In the shopping malls supermarkets ltd. refrigeration space utilization
- display cases The secondary faulty machine has a large noise
- Display cooler secondary failure machine has high noise (two)
- Various techniques for using display cases in daily life
- Why is the temperature drop of the newly opened refrigerator very slow?
- Plant-based foods in walk-in cooler
Latest news articles
- May 2011 refrigerated showcase Qingyuan Tour
- refrigerated showcase Refrigeration Equipment Co., Ltd. growth process
- Refrigerated showcase major sales walk - cooler in class
- Refrigerated showcase display cooler written commercial display cooler legend
- Refrigerated showcase walk - in cooler energy-saving progresses steadily
- 2012 take care of the old man from the supermarket refrigerated showcase
- refrigerated showcase Tip: Which fruits are not suitable for placing in the fruit refrigerated showcase
- Dragon fruit reveals ark makes pitaya ornamental fruit
- Watermelon fresh-keeping refrigerator can better preserve the nutrients of watermelon
- Represent the frozen watermelon fruit for storage
- Hairy crabs freezer frozen taste more fresh
- How hairy crabs fresh refrigerated showcase display cooler tell you
- Large supermarket display ark how to choose the right goods
- Small convenience store owner should show how to choose the convenience stores ltd. refrigeration
- Refrigerated showcase ltd. refrigeration has been a leader in innovation and energy saving
- In September 2012, refrigerated showcase west chung
- Refrigerated showcase walk - in cooler cleaner which aspects should be paid attention to
- Correctly use refrigerated showcase supermarket refrigerated showcase the matters needing attention
- , a refrigerated display showcase meat cooler features of the product
- Refrigerated showcase walk - in the cooler is icy